MATERIAL SAFETY DATA SHEET U.S. DEPARTMENT OF LABOR COMPLIES WITH USDL SAFETY AND HEALTH REGULATIONS, (29 CFR 1910.1200) IMPORTANT! THIS IS YOUR ONLY COPY. PLEASE DISTRIBUTE TO ALL PLANT LOCATIONS CODE #:5375 REV: 002 DATE SENT: 11/27/06 ************************************************************************** SECTION I: PRODUCT DESCRIPTION:NO. 5375 CLEAN FAST (AERO) MANUFACTURER: HILL MFG CO., INC. 1500 JONESBORO ROAD ATLANTA, GA 30315 EMERGENCY (800) 535-5053 M-F:9-5 (404) 522-8364 PREPARED BY: RICK GLISSON DATE PREPARED: 02/28/03 ************************************************************************** SECTION II: HAZARDOUS INGREDIENTS: CAS #: %: TLV SARA III,#313 N-PROPYL BROMIDE 106-94-5 >1 NE 1,3 DIOXOLARE 646-06-0 NE CARBON DIOXIDE 124-38-9 >1 5000 PPM HMIS RATING: HEALTH 2, FIRE: 0, REACTIVITY 0, PERSONAL PROTECTION B ************************************************************************** SECTION III: PHYSICAL DATA BOILING POINT (DEG. F.): 154 VAPOR PRESSURE (MM HG.): 110 MMHG @ 20 DEG C (CAN PRESSURE 85-95 PSI) VAPOR DENSITY (AIR=1): 4.3 SOLUBILITY IN WATER: NIL SPECIFIC GRAVITY (H2O=1): 1.23-1.26 PERCENT VOLATILE BY VOLUME (%): 100 EVAPORATION RATE (BUAC=1): >1 APPEARANCE AND ODOR: CLEAR COLORLESS THIN LIQUID WITH SWEETISH ODOR PH: N/A ************************************************************************** SECTION IV: FIRE AND EXPLOSION DATA FLASH POINT (METHOD USED): CONCENTRATE: NONE, PROPELLANT: DOES NOT FLASH FLAMMABLE LIMITS: LEL: 2.0% UEL: 5.0% (CONCENTRATE) EXTINGUISHING MEDIA: WATER FOG SPECIAL FIRE FIGHTING PROCEDURES: WATER MAY BE USED TO KEEP FIRE-EXPOSED CONTAINERS COOL UNTIL FIRE IS OUT. SELF-CONTAINED BREATHING APPARATUS WITH FULL FACEPIECE OPERATED IN PRESSURE DEMAND OR OTHER POSITIVE PRESSURE MODE. UNUSUAL FIRE & EXPLOSION HAZARDS: TEMPERATURES OVER 120 DEG. F. MAY CAUSE CAN TO BURST. WILL FORM FLAMMABLE MIXTURE WITH AIR BETWEEN 2.0-5.0% BY VOLUME. AVOID CONTACT WITH FLAMES, SPARKS OR HIGH INTENSITY HEAT SOURCES. CONTENTS UNDER PRESSURE. DO NOT PUNCTURE OR INCINERATE CONTAINER. TRANSPORTATION: DOT HAZARD CLASSIFICATION: ORM-D MATERIAL SAFETY DATA SHEET NO. 5375 CLEAN FAST (AERO) PAGE 2 ************************************************************************** SECTION V : HEALTH HAZARD DATA THRESHOLD LIMIT VALUE: 5000 PPM (CARBON DIOXIDE PROPELLANT) EFFECTS OF OVEREXPOSURE: EYES: MAY CAUSE IRRITATION OR PAIN. PRE-EXISTING CONDITIONS MAY HAVE INCREASED SUSCEPTIBILITY TO THE HAZARDS OF EXCESSIVE EXPOSURE. SKIN: PROLONGED CONTACT MAY PRODUCE IRRITATION AND DISCOMFORT OR RASH. INGESTION: MAY RESULT IN IRRITATION OF THE MOUTH & GASTROINTESTINAL TRACT. INHALATION: BREATHING LARGE AMOUNTS ARE IRRITATING TO THE RESPIRATORY TRACT. MAY CAUSE HEADACHE, DIZZINESS, NAUSEA, VOMITING OR NARCOSIS IN CONFINED OR POORLY VENTILATED AREAS. PRE-EXISTING CONDITIONS MAY HAVE INCREASED SUSCEPTIBILITY TO THE HAZARDS OF EXCESSIVE EXPOSURE. EMERGENCY & FIRST AID PROCEDURES: SKIN: THOROUGHLY WASH EXPOSED AREA WITH SOAP & WATER. EYES: IRRIGATE EYES FOR MINIMUM 15 MINUTES. CALL A PHYSICIAN INGESTION: IF SWALLOWED, IF INDIVIDUAL IS CONSCIOUS, DO NOT INDUCE VOMITING HAVE INDIVIDUAL DRINK LARGE AMOUNT OF WATER. CALL A PHYSICIAN. INHALATION: REMOVE TO FRESH AIR. PROVIDE OXYGEN IF BREATHING IS DIFFICULT ADMINISTER CPR IF INDIVIDUAL IS NOT BREATHING. GET MEDICAL ATTENTION. CARCINOGENICITY: NONE KNOWN. PRIMARY ROUTE OF EXPOSURE: SKIN, INHALATION AND EYES. ************************************************************************** SECTION VI : REACTIVITY DATA STABILITY: STABLE CONDITIONS TO AVOID: TEMPERATURES OVER 120 DEG. F. MAY CAUSE CAN TO BURST. INCOMPATABILITY: AVOID CONTACT WITH STRONG OXIDIZERS, STRONG ACIDS, STRONG BASES, REACTIVE METALS, NATURAL RUBBER, FREE WATER, OPEN FLAME, ELECTRIC ARC OR OTHER HIGH ENERGY IGNITION SOURCE OR HOT SURFACE THAT COULD CAUSE TERMAL DECOMPOSITION. HAZARDOUS DECOMPOSITION PRODUCTS: CO, CO2, HYDROCARBONS, HYDROGEN HALIDE & BROMIDES. HAZARDOUS POLYMERIZATION: WILL NOT OCCUR. CONDITIONS TO AVOID: NONE ************************************************************************** SECTION VII: SPILL OR LEAK PROCEDURES STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED: PROCEDURES FOR CLEANING UP LEAKS AND SPILLS: ABSORB SPILL WITH INERT MATERIAL THEN PLACE IN A CHEMICAL WASTE CONTAINER. DISPOSE OF SPILL MATERIAL IN ACCORDANCE WITH STATE, FEDERAL AND LOCAL REGULATIONS. ************************************************************************** SECTION VIII: SPECIAL PROTECTION INFORMATION ENGINEERING CONTROLS: MAINTAIN ADEQUATE VENTILATION. VENTILATION: PROVIDE SUFFICIENT VENTILATION TO MAINTAIN EXPOSURE. PROTECTIVE GLOVES: CHEMICAL RESISTANT IF REPEATED SKIN CONTACT OCCURS EYE PROTECTION: CHEMICAL SPLASH PROOF GOGGLES OR SAFETY GLASSES OTHER PROTECTIVE EQUIPMENT: USE RESPIRATOR ONLY AS A LAST RESORT TO CONTROL EXPOSURE. ************************************************************************** SECTION IX: SPECIAL PRECAUTIONS PRECAUTIONS TO BE TAKEN IN HANDLING & STORING: DO NOT USE OR STORE NEAR FIRE, SPARKS OR FLAME. DO NOT PUNCTURE OR INCINERATE CONTAINER. OTHER PRECAUTIONS: KEEP OUT OF REACH OF CHILDREN. FOR COMMERCIAL/INDUSTRIAL USE ONLY.